54
No. Function name
Changes
during RUN
Setting range Unit
Initial
value
P312
12th Step Speed
Frequency
○ 0.0, 0.2 to 400.0 0.1[Hz] 32.5
P313
13th Step Speed
Frequency
○ 0.0, 0.2 to 400.0 0.1[Hz] 35.0
P314
14th Step Speed
Frequency
○ 0.0, 0.2 to 400.0 0.1[Hz] 40.0
P315
15th Step Speed
Frequency
○ 0.0, 0.2 to 400.0 0.1[Hz] 45.0
P316
16th Step Speed
Frequency
○ 0.0, 0.2 to 400.0 0.1[Hz] 50.0
P317
2nd Acceleration
Time
○ 0.04 to 3600
0.01[sec]*9
*4
P318
2nd Deceleration
Time
○ 0.04 to 3600
0.01[sec]*9
*4
P319
3rd Acceleration
Time
○ 0.04 to 3600
0.01[sec]*9
*4
P320
3rd Deceleration
Time
○ 0.04 to 3600
0.01[sec]*9
*4
P321
4th Acceleration
Time
○ 0.04 to 3600
0.01[sec]*9
*4
P322
4th Deceleration
Time
○ 0.04 to 3600
0.01[sec]*9
*4
P323
Rotation Direction
of
Timer Operation
- 0 to 255 - 0
P324
Continuous
Operation Times of
Timer
○ 0 · 1 to 9999 1[times] 1
P325
Continuous
Operation Mode of
Timer
○
0: Return to zero dead stop status and
then start next cycle.
1: Change to 1st multi-step speed
frequency for the next cycle.
- 0
P326
Continuous Standby
Time of Timer
Operation
○ 0.0 · 0.1 to 6553 0.1[sec] 0.0
P327
1st Step Speed
Runtime
○ 0.0 · 0.1 to 6553 0.1[sec] 0.0
P328
2nd Step Speed
Runtime
○ 0.0 · 0.1 to 6553 0.1[sec] 0.0
P329
3nd Step Speed
Runtime
○ 0.0 · 0.1 to 6553 0.1[sec] 0.0
P330
4nd Step Speed
Runtime
○ 0.0 · 0.1 to 6553 0.1[sec] 0.0
P331
5nd Step Speed
Runtime
○ 0.0 · 0.1 to 6553 0.1[sec] 0.0
P332
6nd Step Speed
Runtime
○ 0.0 · 0.1 to 6553 0.1[sec] 0.0