8
Model
Indoor CS-PC24TKF
Outdoor CU-PC24TKF
Dimension
Height (I/D / O/D) mm (inch) 302 (11-29/32) / 695 (27-3/8)
Width (I/D / O/D) mm (inch) 1102 (43-13/32) / 875 (34-15/32)
Depth (I/D / O/D) mm (inch) 244 (9-5/8) / 320 (12-5/8)
Weight Net (I/D / O/D) kg (lb) 12 (26) / 54 (119)
Piping
Pipe Diameter (Liquid / Gas) mm (inch) 6.35 (1/4) / 15.88 (5/8)
Standard length m (ft) 5.0 (16.4)
Length range (min – max) m (ft) 3 (9.8) ~ 30 (98.4)
I/D & O/D Height different m (ft) 20 (65.6)
Additional Gas Amount g/m (oz/ft) 30 (0.3)
Length for Additional Gas m (ft) 7.5 (24.6)
Drain Hose
Inner Diameter mm 16.0
Length mm 650
Indoor Heat
Exchanger
Fin Material Aluminium (Pre coated)
Fin Type Slit Fin
Row × Stage × FPI 2 × 17 × 17
Size (W × H × L) mm 836 × 357 × 25.4
Outdoor
Heat
Exchanger
Fin Material Aluminium (Blue coated)
Fin Type Slit Fin
Row × Stage × FPI 2 × 31 × 17
Size (W × H × L) mm 25.4 × 651 × 866.6:846.6
Air Filter
Material Polypropelene
Type One-touch
Power Supply Indoor
Power Supply Cord A 20
Thermostat -
Protection Device Mechanical
DRY BULB WET BULB
Indoor Operation Range
Maximum
°C (°F)
32 (89.6) 23 (73.4)
Minimum
°C (°F)
16 (60.8) 11 (51.8)
Outdoor Operation Range
Maximum
°C (°F)
55 (131) 31 (87.8)
Minimum
°C (°F)
16 (60.8) 11 (51.8)
1. Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb) and outdoor air
temperature of 35°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb).
2.
Specifications are subjected to change without prior notice for further improvement.