10
3. Specifications
Model
Indoor CS-Z25YKEA
Outdoor CU-Z25YKEA
Performance Test Condition EUROVENT
Power Supply
Phase, Hz Single, 50
V 230
Min. Mid. Max.
Cooling
Capacity
kW 0.85 2.50 3.50
BTU/h 2900 8530 11900
kcal/h 730 2150 3010
Running Current A - 2.35 -
Input Power W 180 510 880
Annual Consumption kWh - 255 -
EER Class - A -
EER
W/W 4.72 4.90 3.98
BTU/hW 16.11 16.73 13.52
kcal/hW 4.06 4.22 3.42
ErP
Pdesign kW 2.5
SEER (W/W) 9.5
Annual Consumption kWh 92
Class A+++
Power Factor % - 94 -
Indoor Noise (H / L / QLo)
Pressure Level dB (A) 39 / 25 / 21
Power Level dB (A) 55 / - / -
Outdoor Noise (H / L / QLo)
Pressure Level dB (A) 46 / - / -
Power Level dB (A) 61 / - / -
Heating
Capacity
kW 0.85 3.40 5.00
BTU/h 2900 11600 17100
kcal/h 730 2920 4300
Running Current A - 3.25 -
Input Power W 180 700 1.26k
COP CLASS - A -
COP
W/W 4.72 4.86 3.97
BTU/hW 16.11 16.57 13.57
kcal/hW 4.06 4.17 3.41
ErP
Pdesign kW 2.7
Tbivalent °C -10
SCOP (W/W) 4.6
Annual Consumption kWh 822
Class A++
Power Factor % - 94 -
Indoor Noise (H / L / QLo)
Pressure Level dB (A) 41 / 27 / 22
Power Level dB (A) 57 / - / -
Outdoor Noise (H / L / QLo)
Pressure Level dB (A) 48 / - / -
Power Level dB (A) 63 / - / -
LOW Temp: Capacity (kW) / I. Power (W) / COP 3.62 / 1.12k / 3.23
EXTR LOW Temp: Capacity (kW) / I. Power (W) / COP 3.05 / 1.10k / 2.77
Max Current (A) / Max Input Power (W) 5.6 / 1.26k
Starting Current (A) 3.25