Model
Indoor CS-Z35YKEA
Outdoor CU-Z35YKEA
Performance Test Condition EUROVENT
Power Supply
Phase, Hz Single, 50
V 230
Min. Mid. Max.
Cooling
Capacity
kW 0.85 3.50 4.20
BTU/h 2900 11900 14300
kcal/h 730 3010 3610
Running Current A - 3.80 -
Input Power W 180 850 1.14k
Annual Consumption kWh - 425 -
EER CLASS - A -
EER
W/W 4.72 4.12 3.68
BTU/hW 16.11 14.00 12.54
kcal/hW 4.06 3.54 3.17
ErP
Pdesign kW 3.5
SEER (W/W) 9.6
Annual Consumption kWh 128
Class A+++
Power Factor % - 97 -
Indoor Noise (H / L / QLo)
Pressure Level dB (A) 42 / 28 / 21
Power Level dB (A) 58 / - / -
Outdoor Noise (H / L / QLo)
Pressure Level dB (A) 48 / - / -
Power Level dB (A) 63 / - / -
Heating
Capacity
kW 0.85 4.00 5.80
BTU/h 2900 13600 19800
kcal/h 730 3440 4990
Running Current A - 4.00 -
Input Power W 180 900 1.50k
COP CLASS - A -
COP
W/W 4.72 4.44 3.87
BTU/hW 16.11 15.11 13.20
kcal/hW 4.06 3.82 3.33
ErP
Pdesign kW 3.2
Tbivalent °C -10
SCOP (W/W) 4.6
Annual Consumption kWh 974
Class A++
Power Factor % - 98 -
Indoor Noise (H / L / QLo)
Pressure Level dB (A) 43 / 30 / 22
Power Level dB (A) 59 / - / -
Outdoor Noise (H / L / QLo)
Pressure Level dB (A) 50 / - / -
Power Level dB (A) 65 / - / -
LOW Temp: Capacity (kW) / I. Power (W) / COP 4.20 / 1.33k / 3.16
EXTR LOW Temp: Capacity (kW) / I. Power (W) / COP 3.40 / 1.30k / 2.62
Max Current (A) / Max Input Power (W) 6.6 / 1.50k
Starting Current (A) 4.00