EasyManua.ls Logo

Panasonic CS-Z25YKEA - Page 59

Panasonic CS-Z25YKEA
201 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
59
12.2.4.1 Wire Stripping Connecting and Requirement
Do not joint wires.
OR
OR
OR
Use complete wire without joining.
Use approved socket and plug with earth pin.
Wire connection in this area must follow to national wiring rules.
5 mm or more
Indoor/outdoor
connection
terminal board
(gap between wires)
No loose
strand when
inserted
10 ± 1 mm
Wire stripping
ACCEPT
Conductor
fully inserted
PROHIBITED
Conductor
over inserted
PROHIBITED
Conductor not
fully inserted
WARNING
RISK OF FIRE
JOINING OF WIRES
MAY CAUSE
OVERHEATING AND
FIRE.

Table of Contents

Other manuals for Panasonic CS-Z25YKEA

Related product manuals