5-18
For GT02, GT02L, GT03-E, GT05, GT12, GT32, GT32-R and GT32-E
Cannot be executed
due to operation mode.
(The PLC received the
command that cannot
be executed in the
operation mode.)
Change the mode of the PLC from the operation mode to the
monitor mode.
Data error
A data error occurred
during communication
Check for errors in the communication conditions settings.
Overrun error
The GT cannot receive
data.
PLC runaway might be the problem.
Numerical data error
Designated read/write
area is wrong.
Verify whether or not the reference device used with the basic
communication area and each part is a readable and writable
area.
Error codes other than these are based on Omron PLC error codes.
Be sure to used the PLC in monitor mode. Otherwise, communication will not work properly.
When Connected to a PLC Made by Toshiba Machine Co., Ltd.
For GT02, GT02L, GT03-E, GT05, GT12, GT32, GT32-R and GT32-E
The specified parameter does not exist, or it cannot be used.