With KX-T7600 Series DPT (except KX-T7600E Series)
Using a Modular T-Adaptor
To DLC8/DLC16 card
To DHLC4 card
(for connection of SLT)
4-conductor wiring cord
Connect pins "D1" and "D2".
Slave DPT
SLT
Master DPT
Modular
T-Adaptor
4-conductor wiring cord
Connect pins "D1" and
"D2".
2-conductor wiring cord
Connect pins "T" and "R".
Slave DPTMaster DPT
TO MAIN UNIT
/ PABX
TO TEL
TO MAIN UNIT
/ PABX
Cable Maximum Distance
ø 0.4 mm: 30 m
ø 0.5 mm: 50 m
ø 0.6 mm: 60 m
CAT 5: 50 m
Back View of DPTs
To DLC8/DLC16 card
To DHLC4 card
(for connection of SLT)
108 Installation Manual
3.8.3 Digital EXtra Device Port (Digital XDP) Connection