2.4 Installation of the Trunk Cards
102 Installation Manual
LED Indications
Indication Colour Description
CARD STATUS Green/Red Card status indication
OFF: Power Off
Green ON: Normal (all ports are idle)
Green Flashing (60 times per minute): Normal (a port is in use)
Red ON: Fault (includes reset)
Red Flashing (60 times per minute): Out of Service
ONLINE Green On-line status indication
ON: On-line mode
Flashing: Emergency maintenance mode
ALARM Red Alarm indication
OFF: Normal
ON: Alarm
IAM BUSY Green Busy status indication
OFF: Not used
ON: At least one line is used
LINK Green Link status indication
OFF: Connection error
ON: Normal connection
DATA Green Data transmission indication
OFF: No data transmitted
ON: Data transmitting
COL Green Data collision indication
OFF: No data collision
ON: Data collision
SIOSEL Green Serial maintenance port status indication
OFF: CPU power port used (maintenance port not available)
ON: Maintenance port available

Table of Contents