SR-DSV10739 - 13 -
# ## Motor Business Unit, Home Appliances Company, Panasonic
# 6-3 Encoder Connector X3
Description
Connector
Pin No.
Symbol
1 E5V
Encoder power supply output
2
E0V (*
Remark
1)
3
$$
$$
4
$$
5 PS
Encoder Signal input/out put
(Serial Signal)
6 /PS
Frame ground shell FG
* Remark 1) The E0V of the encoder power supply output is connected with the control circuit ground of the
connector
X3 .
6-4 Motor and Power Connector# X4
Size B,C of 200V System
Terminal#
Symbol
Terminal Name
Description
U(red)
V(gray)
W(black)
Motor connection
Connect each phase of the motor winding.
U: U phase V: V phase W: W phase
B1(gray)
B2(gray)
Regen. resistor
connection
If the drive gets over regeneration alarm, connect an external regen resistor
(prepared by customer) between B1 and B2.
L1C(red) + 5%
L2C(red)
Control power
supply input
220V
Single phase 220%240&
- 10%
, 50/60Hz input
L1(black) + 5%
X4
L2(black)
Main power supply
input
220V
Single phase 220%240&
- 10%
, 50/60Hz input
Earth
Earth terminal for grounding'
Please select the ferrule length between 12mm ~ 15mm. Short ferrule pins can not be fixed during the insertion.
Ferrule pin of DNH4 -112 made in DINKEL (4mm diameter) is recommended.
(Tighten the fixing screws to the case at screw torque of 0.4%0.6N)m or less.
(While not use the IHUUXOH pin, ensure that all the cables into the connector, to avoid short circuits.
#
#
#
#
#
#
#
#
#
#
#
#
#
#