EasyManua.ls Logo

Panasonic LIQI - Real-Time Auto Tuning Estimation Speed; Oscillation Detection Level; Warning Mask Setup

Panasonic LIQI
35 pages
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
LIQI
Page 16
Pr6.31 Real-time auto tuning estimation speed
Range Default Unit
0 – 3 1 -
0 : No change
1 : Almost constant
2 : Slower change
3 : Faster change
Pr6.37 Oscillation detection level
Range Default Unit
0.0 – 100.0 0.0 %
Pr6.38 Warning mask setup
Range Default Unit
-32768 – 32768 4 -
* for more detail please refer Panasonic A5 manual