Pr2.22 Positional command smoothing filter
Range Default Unit
0 – 10000 0 0.1ms
Pr2.23 Positional command FIR filter
Range Default Unit
0 – 10000 0 0.1ms
Pr4.00 SI1 input selection
Range Default Unit
0 – 16777225 3 -
Pr4.01 SI2 input selection
Range Default Unit
0 – 16777225 4 -
Pr4.02 SI3 input selection
Range Default Unit
0 – 16777225 7 -
Pr4.03 SI4 input selection
Range Default Unit
0 – 16777225 136 -
Pr4.04 SI5 input selection
Range Default Unit
0 – 16777225 130 -
Pr4.05 SI6 input selection
Range Default Unit
0 – 16777225 129 -
Pr4.10 S01 output selection
Range Default Unit
0 – 16777225 1 -
Pr4.11 SO2 output selection
Range Default Unit
0 – 16777225 4 -
Pr4.12 SO3 output selection
Range Default Unit
0 – 16777225 2 -
* for more detail please refer Panasonic A5 manual