Chapter 4 Settings — [NETWORK] menu
154 - ENGLISH
[NETWORK] menu
On the menu screen, select [NETWORK] from the main menu, and select an item from the sub-menu.
Refer to “Navigating through the menu” (x page 77) for the operation of the menu screen.
[DIGITAL LINK MODE]
Switch the communication method of the <DIGITAL LINK/LAN> terminal of the projector.
1) Press as to select [DIGITAL LINK MODE].
2) Press qw to switch the item.
f The items will switch each time you press the button.
[AUTO] Switches the communication method automatically to DIGITAL LINK, long reach, or Ethernet.
[DIGITAL LINK] Fixes the communication method to DIGITAL LINK.
[LONG REACH] Fixes the communication method to long reach.
[ETHERNET] Fixes the communication method to Ethernet.
Possible communication modes
l: Communication possible
―: Communication not possible
Setting
Communication possible
Video transfer
(100 m (328'1"))
Video transfer
(150 m (492'2"))
Ethernet RS-232C
[AUTO]
For DIGITAL LINK
l
―
l l
For long reach ―
l l l
For Ethernet ― ―
l
―
[DIGITAL LINK]
l
―
l l
[LONG REACH] ―
l l l
[ETHERNET] ― ―
l
―
Note
f The maximum transmission distance when connected with the long-reach communication method is 150 m (492'2"). However, the signal
that the projector can receive is only up to 1080/60p (148.5 MHz).
f If the communication method is set to long reach at the twist-pair-cable transmitter, connection will be made with long-reach communication
method when [DIGITAL LINK MODE] is set to [AUTO]. To connect the projector to the optional DIGITAL LINK Switcher (Model No.:
ET-YFB200G) with the long-reach communication method, set [DIGITAL LINK MODE] to [LONG REACH].
f Connection will not be made correctly if the twist-pair-cable transmitter is not supporting the long-reach communication method even if
[DIGITAL LINK MODE] is set to [LONG REACH].
[DIGITAL LINK SETUP]
Set the communication method of DIGITAL LINK or Ethernet.
When the projector is connected directly via Ethernet
1) Press as to select [DIGITAL LINK SETUP].
2) Press the <ENTER> button.
f The [DIGITAL LINK SETUP] screen is displayed.
3) Press as to select [DUPLEX(ETHERNET)].
4) Press qw to switch the communication method.
f The items will switch each time you press the button.
[AUTONEGOTIATION] Sets the communication method automatically.
[100BaseTX-Full] Sets full-duplex communication method.
[100BaseTX-Half] Sets half-duplex communication method.
5) Press as to select [STORE].