Chapter 7Appendix — Technical information
188 - ENGLISH
r
[AUDIO VOLUME]
Performance Parameter Default value
No operation 0-31
0
Factory default setting 32-63
0 64-65
63 190-191
No operation 192-255
r
ENABLE / DISABLE
Operation for all channels is not accepted when set to “Disable”.
Performance Parameter Default value
Disable 0-127
0
Enable 128-255
Note
f
If the projector is operated using the remote control or the control panel, or by the control command while controlling the projector using the
Art-Net function, the setting of the DMX controller or computer application may be different from the projector status. To reect the controls
of all channels to the projector, set “ENABLE / DISABLE” of channel 11 to “Disable” and then back to “Enable”.
f
To create and register the USER LOGO image, use “Logo Transfer Software”. The software can be downloaded from the Panasonic website
(https://panasonic.net/cns/projector/).
Control commands via LAN
The projector can be controlled via the <DIGITAL LINK/LAN> terminal or the <LAN> terminal by using the control
command format via the <SERIAL/MULTI SYNC IN> terminal.
For examples of the available commands, refer to “Control command” (
x
page 194).
Note
f
Setting the password of the administrator account is required (
x
page 137) for sending and receiving the commands via LAN.
When connecting in protected mode
Connecting
This is the connection method when [NETWORK] menu → [NETWORK SECURITY] → [COMMAND PROTECT]
is set to [ENABLE].
1) Obtain the IP address and port number (Initial set value = 1024) of the projector and request a
connection to the projector.
f
You can obtain both the IP address and the port number from the menu screen of the projector.
IP address
Obtain from the [NETWORK] menu
[NETWORK STATUS].
Port number
Obtain from the [NETWORK] menu
[NETWORK CONTROL]
[COMMAND PORT].
2) Check the response from the projector.
Data section Blank Mode Blank Random number section
Termination
symbol
Command
example
“NTCONTROL”
(ASCII string)
‘ ’
0x20
‘1’
0x31
‘ ’
0x20
“zzzzzzzz”
(ASCII code hex number)
(CR)
0x0d
Data length
9 bytes 1 byte 1 byte 1 byte 8 bytes 1 byte
f
Mode: 1 = Protect mode
f
Example: Response during protect mode (random number section is undened value)
“NTCONTROL 1 23181e1e” (CR)
3) Generate a 32-byte hash value from the following data using MD5 algorithm.
f
“xxxxxx:yyyyy:zzzzzzzz”