Chapter 7 Appendix — Technical information
240 - ENGLISH
Class
Command
Control details
Parameter/response
string
Remark
1 NAME ? Projector name query xxxxx
Returns the name set in [PROJECTOR NAME] of [NETWORK
SETUP].
1 INF1 ?
Manufacturer name
query
Panasonic Returns manufacturer name.
1 INF2 ? Model name query PT-RQ22K Returns model name.
1 INF0 ?
Other information
queries
xxxxx Returns information such as version number.
1 CLSS ?
Class information
query
2 Returns class for PJLink.
2 SNUM ? Serial number query xxxxxxxxx Returns serial number.
2 SVER ? Software version query xxxxxxxxx Returns version number.
2 INNM ?
Input terminal name
query
31 / SDI1
32 / SDI2
33 / SDI3
34 / SDI4
35 / DIGITAL LINK
36 / SLOT1-1
SLOT1-1 (name of the input 1 of the Interface Board installed in
<SLOT 1>)
37 / SLOT1-2
SLOT1-2 (name of the input 2 of the Interface Board installed in
<SLOT 1>)
38 / SLOT1-3
SLOT1-3 (name of the input 3 of the Interface Board installed in
<SLOT 1>)
39 / SLOT1-4
SLOT1-4 (name of the input 4 of the Interface Board installed in
<SLOT 1>)
3A / SLOT2-1
SLOT2-1 (name of the input 1 of the Interface Board installed in
<SLOT 2>)
3B / SLOT2-2
SLOT2-2 (name of the input 2 of the Interface Board installed in
<SLOT 2>)
3C / SLOT2-3
SLOT2-3 (name of the input 3 of the Interface Board installed in
<SLOT 2>)
3D / SLOT2-4
SLOT2-4 (name of the input 4 of the Interface Board installed in
<SLOT 2>)
2 IRES ?
Input signal resolution
query
AAAAxBBBB
AAAA: Horizontal resolution
BBBB: Vertical resolution
2 RRES ?
Recommended
resolution query
3840x2400
2560x1600
Returns display resolution.
3840x2400: When [QUAD PIXEL DRIVE] is set to [ON]
2560x1600: When [QUAD PIXEL DRIVE] is set to [OFF]
2
FREZ Freeze control
0
1
Freeze clear
Freeze (stop)
FREZ ? Freeze status query
2 POWR
Cooling notication 0 Noties when the power is turned off.
Warmup notication 1 Noties when the power is turned on.
2 ERST Error notication xxxxxx Noties when an error occurs.
2 LKUP Link up notication xx:xx:xx:xx:xx:xx
Noties the MAC address when the PJLink communication
becomes possible.
2 INPT
Input switch
completion notication
31 SDI1
32 SDI2
33 SDI3
34 SDI4
35 DIGITAL LINK
36 SLOT1-1 (input 1 of the Interface Board installed in <SLOT 1>)
37 SLOT1-2 (input 2 of the Interface Board installed in <SLOT 1>)
38 SLOT1-3 (input 3 of the Interface Board installed in <SLOT 1>)
39 SLOT1-4 (input 4 of the Interface Board installed in <SLOT 1>)
3A SLOT2-1 (input 1 of the Interface Board installed in <SLOT 2>)
3B SLOT2-2 (input 2 of the Interface Board installed in <SLOT 2>)
3C SLOT2-3 (input 3 of the Interface Board installed in <SLOT 2>)
3D SLOT2-4 (input 4 of the Interface Board installed in <SLOT 2>)
2 SRCH Projector search
ACKN=xx:xx:xx:xx:xx:xx
The projector connected to the same network that can
communicate with PJLink will respond with its MAC address.
*1 When the optional Interface Board for 12G-SDI (Model No.: ET-MDN12G10) is installed, this corresponds to the input switch for the <SDI 1 IN>
terminal. Switching to the <SDI 2 IN/1 OUT> terminal or the <SDI 4 IN/3 OUT> terminal is not possible.