Chapter 7 Appendix — Technical information
296 - ENGLISH
Control details
Art-Net channel setting
[1] [2] [3] [USER]
LENS V SHIFT LSB ― ― ―
l
*1
LENS FOCUS MSB ― ―
l l
*1
LENS FOCUS LSB ― ―
l l
*1
LENS ZOOM MSB ― ―
l l
*1
LENS ZOOM LSB ― ―
l l
*1
ENABLE/DISABLE
l l l l
*1 These items can be controlled in following case.
When the standard DC motor unit installed in the Zoom Lens (Model No.: ET-D75LE6, ET-D75LE8, ET-D75LE10, ET-D75LE20, ET-D75LE30,
ET-D75LE40) is replaced with the stepping motor unit using the Stepping Motor Kit (Model No.: ET-D75MKS10), or when a projection lens with the
stepping motor is attached.
Control details
r LIGHT OUTPUT
This can be set in 256 steps between 100 % and 0 %.
Performance Parameter Default value
100 % 0
0… …
0 % 255
r INPUT SELECT (when [Art-Net CHANNEL SETTING] is set to [1])
Performance Parameter Default value
No operation 0-39
0HDMI 40-47
No operation 48-255
r INPUT SELECT (when [Art-Net CHANNEL SETTING] is set to anything other than [1])
Performance Parameter Default value
No operation 0-31
0
HDMI 32-39
DIGITAL LINK 40-47
No operation 48-79
SLOT1-1
*1
80-87
SLOT1-2
*1
88-95
SLOT2-3
*2
96-103
SLOT2-4
*2
104-111
No operation 112-151
SLOT1-1
*3
152-159
SLOT1-2
*3
160-167
SLOT1-3
*3
168-175
SLOT1-4
*3
176-183
SLOT2-1
*4
184-191
SLOT2-2
*4
192-199
SLOT2-3
*4
200-207
SLOT2-4
*4
208-215
No operation 216-255
*1 When the Interface Board equipped with two inputs is installed in <SLOT 1>, the input is switched to the specied input of the Interface Board.
*2 When the Interface Board equipped with two inputs is installed in <SLOT 2>, the input is switched to the specied input of the Interface Board.
*3 When the Interface Board equipped with four inputs is installed in <SLOT 1>, the input is switched to the specied input of the Interface Board.
*4 When the Interface Board equipped with four inputs is installed in <SLOT 2>, the input is switched to the specied input of the Interface Board.