Chapter 7Appendix — Technical information
302 - ENGLISH
Data section Blank Mode
Termination
symbol
Command
example
“NTCONTROL”
(ASCII string)
‘ ’
0x20
‘0’
0x30
(CR)
0x0d
Data length 9 bytes 1 byte 1 byte 1 byte
f Mode: 0 = Non-protect mode
f Example: Response during non-protect mode
“NTCONTROL 0” (CR)
Command transmission method
Transmit using the following command formats.
r Transmitted data
Header Data section
Termination
symbol
Command
example
‘0’
0x30
‘0’
0x30
Control command
(ASCII string)
(CR)
0x0d
Data length 1 byte 1 byte Undened length 1 byte
f Example: Transmission of power supply status acquisition command
“00QPW” (CR)
r Received data
Header Data section
Termination
symbol
Command
example
‘0’
0x30
‘0’
0x30
Control command
(ASCII string)
(CR)
0x0d
Data length 1 byte 1 byte Undened length 1 byte
f Example: The projector is in standby status
“00000” (CR)
r Error response
String Details
Termination
symbol
Message
“ERR1” Undened control command
(CR)
0x0d
“ERR2” Out of parameter range
“ERR3” Busy state or no-acceptable period
“ERR4” Timeout or no-acceptable period
“ERR5” Wrong data length
Data length 4 bytes 1 byte
Note
f The projector will automatically disconnect the connection with the network right after sending the command. This is the specication based
on the security view point to prevent unauthorized operation of this product by a malicious third party. To send commands continuously,
execute the network connection request every time the command is to be sent. For details, refer to “Communication ow between server
and client” (x page 303).