Control commands via LAN
You can also control via the <LAN> terminal by using the control command format via the <SERIAL IN> terminal.
For examples of the available commands, refer to “Control commands” (x page 124).
When web control administrator rights password is set (Protect mode)
Connection method
1) Obtain the IP address and port number (Initial set value = 1 024) of the projector and make a request
for connection to the projector.
f Acquire the IP address from the menu screen of the projector, and the port number from the web control
page.
IP address :
Obtain from the [NETWORK/USB] menu → [STATUS]
Port No. :
Obtain from [Detailed set up] → [Port set up] page of the web control
2) Check the response from the projector.
Data section Blank Mode Blank Random number section Termination symbol
Command
example
“NTCONTROL”
(ASCII string)
‘ ’
0x20
‘1’
0x31
‘ ’
0x20
“zzzzzzzz”
(ASCII code hexadecimal
number)
(CR)
0x0d
Data length 9 bytes 1 byte 1 byte 1 byte 8 bytes 1 byte
f Mode : 1 = Protect mode
3) Generate a 32-byte hash value from the following data using MD5 algorithm.
f “xxxxxx:yyyyy:zzzzzzzz”
xxxxxx :
Administrator rights user name for web control (Default user name is “dispadmin”)
yyyyy :
Password of above administrator rights user (Default password is “@Panasonic”)
zzzzzzzz :
8-byte random number obtained in Step 2)
Command data format
It is the data format used for sending and receiving commands.
r Transmitted data
Header Data section Termination symbol
Command
example
Hash value
(See above
"Connection method")
‘0’
0x30
‘0’
0x30
Control command
(ASCII string)
(CR)
0x0d
Data length 32 bytes 1 byte 1 byte Undened length 1 byte
r Received data
Header Data section Termination symbol
Command
example
‘0’
0x30
‘0’
0x30
Control command
(ASCII string)
(CR)
0x0d
Data length 1 byte 1 byte Undened length 1 byte
r Error response
String Details Termination symbol
Message
"ERR1" Undened control command
(CR)
0x0d
"ERR2" Out of parameter range
"ERR3" Busy state or no-acceptable period
"ERR4" Timeout or no-acceptable period
"ERR5" Wrong data length
"ERRA" Password mismatch
Data length 4 bytes ― 1 byte
120 - ENGLISH
Chapter 7 Appendix - Technical Information