EasyManua.ls Logo

Panasonic SOLID SHINE PT-VMZ51 - Air Filter Unit Installation and Counter Reset; Attaching the Air Filter Unit and Cover; Resetting the Air Filter Usage Counter

Panasonic SOLID SHINE PT-VMZ51
170 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Attention
f After washing the air lter unit, dry it thoroughly before attaching it back to the projector. Attaching a wet unit will cause an electric shock or
malfunction.
f Do not disassemble the air lter unit.
Note
f Replace the air lter unit with a new optional Replacement Filter Unit (Model No.: ET-RFV500) if it is damaged or if the dirt does not come
off even after washing
Attaching the air lter unit
Tab
Air lter unit
Sponge
Fig. 1 Fig. 2
1) Attach the air filter unit to the projector. (Fig. 1)
f Hold the air lter unit with the tab on the left side as shown in the gure, attach it from the right side, and
push the tab until it clicks.
f Take care not to remove the sponge (Fig. 2) on the side of the air lter unit when attaching the air lter unit.
f Do not press on the crease part of the air lter when pressing into place.
2) Attach the air filter cover to the projector.
f Perform in the reverse order of the Step 2) of “Removing the air lter unit” (x page 146) to close the air
lter cover. Make sure to press the air lter cover rmly until it clicks into place.
f When the air lter unit is attached to the projector, proceed to the “Resetting the air lter counter” (x page 147).
Note
f When using the projector, be sure to attach the air lter unit. If it is not attached, the projector will suck in dirt and dust causing a malfunction.
Resetting the air lter counter
1) Turn on the projector.
2) Press the <MENU> button on the remote control or the control panel.
f The main menu screen is displayed.
3) Press as to select [PROJECTOR SETUP].
4) Press the <ENTER> button.
f The [PROJECTOR SETUP] screen is displayed.
5) Press as to select [FILTER COUNTER].
6) Press the <ENTER> button.
f The [FILTER COUNTER] screen is displayed.
7) Press as to select [FILTER COUNTER RESET] and press the <ENTER> button.
8) When the confirmation screen is displayed, press qw to select [OK], then press the <ENTER> button.
f The [PROJECTOR SETUP] menu → [FILTER COUNTER] → [FILTER COUNTER] is displayed as “0H”.
Note
f When the projector is used without resetting the lter counter, the actual lter usage time (counter numeric value) will not be able to be conrmed.
ENGLISH - 147
Chapter 6 Maintenance - Maintenance/replacement

Table of Contents

Related product manuals