8 Adjustment Procedure
8.1. Driver Set-up
8.1.1. Item / Preparation
1. Set Aging pattern 0 (Vset adjustment pattern) by IIC mode.
2. Set the picture controls as follows.
· Picture menu : Standard
· Picture : 25
· Aspect : Full
8.1.2. Adjustments
Adjust driver section voltages referring the panel data label.
Caution
1. First perform Vsus voltage adjustment.
2. Confirmation of Vscn voltage should be performed after confirmation of Vad voltage adjustment.
When Vad = -105V, Voltage of Vscn is 40V ± 4V.