Distribution mode example
Up to 20
A
B C D E F G
Control box
Distribution box
DIP switch
*1
Repeat switch
*2
Terminate switch
*3
A
1 2 3 4 5 6 7 8
ON
OFF
(off) (off)
B
1 2 3 4 5 6 7 8
ON
OFF
(off) (off)
C
1 2 3 4 5 6 7 8
ON
OFF
(off) (off)
D
1 2 3 4 5 6 7 8
ON
OFF
(off) (off)
E
1 2 3 4 5 6 7 8
ON
OFF
(off) (off)
F
1 2 3 4 5 6 7 8
ON
OFF
(off) (off)
G
1 2 3 4 5 6 7 8
ON
OFF
(off) (on)
*1 Each DIP switch setting can only be used one time per branch.
The number 8 switch must always be set to the "off" position.
Only one DIP switch is set to the "on" position. All others are set to the "off" position.
*2
In distribution mode, the repeat switch of all distribution boxes in the branch is set to the "off" position.
*3 The terminate switch of the last distribution box in the branch is set to the "on" position. All others are set to the
"off" position.