24
3. Move the cursor to ALARM IN 2, and then tilt the
joystick left and right to select the operation the
camera should perform when an external signal is
receivedbyALARMIN2.
OFF : Ignore alarm input signals.
2POSI : Move to preset position 2.
SEQ : Start sequential movement.
PATROL2 :StartPATROL2.
AUTOTRACK2 : Move to preset position number 2,
and then perform auto tracking.
PATROL2 (S) :Start PATROL 2, and maintain the
stored picture quality settings
(page17)evenaftercompletion.
ThefactorydefaultsettingisOFF.
4. Move the cursor to ALARM IN 3, and then tilt the
joystick left and right to select the operation the
camera should perform when an external signal is
receivedbyALARMIN3.
OFF : Ignore alarm input signals.
3POSI : Move to preset position 3.
SORT : Start sort movement.
PATROL3 :StartPATROL3.
AUTOTRACK3 : Move to preset position number 3,
and then perform auto tracking.
PATROL3 (S) :Start PATROL 3, and maintain the
stored picture quality settings
(page17)evenaftercompletion.
ThefactorydefaultsettingisOFF.
5. MovethecursortoALARMIN4,andthentiltthe
joystick left and right to select the operation the
camerashouldperformwhenanexternalsignalis
receivedbyALARMIN4.
OFF : Ignore alarm input signals.
4POSI : Move to preset position 4.
BW : Black and white display while
signal is being input.
PATROL4 :StartPATROL4.
AUTOTRACK4 : Move to preset position number 4,
and then perform auto tracking.
PATROL4 (S) :Start PATROL 4, and maintain the
stored picture quality settings
(page17)evenaftercompletion.
ThefactorydefaultsettingisOFF.
Notes:
•Use PATROL 1 (S) to 4 (S) if you want to switch
picture quality (for example to switch picture
quality from day to night) when an alarm input is
received.ALARMIN4canbeusedcombinedwith
BW.
To use the camera with this application, set the
picture quality you want to switch before
registering the patrol, then start the patrol
registration and then end the registration
immediately.
•If youwantto change the picturequality settings
accordingtoalarminputforPATROL1(S)to4(S),
the settings are applied to the camera settings
and are kept even after the camera is turned on
again.
•PATROL1(S)-4(S)displaysonlythesetnumberof
patrolroutines(page17).
6. Move the cursor to CNT-CLS 1, and then tilt the
joystick left and right to select the alarm output that
shouldbeperformedoverALARMOUT1whenan
alarm is detected.
OFF :Noalarmoutput
AUX1 :Output a contact close signal when
AUX1 input is received from the system
controller.
ALARM :Output an alarm signal when an alarm is
detectedbythemotiondetector(page22)
or the preset alarm (page 23). After
selecting this setting, perform step 7 to
specify the alarm signal output time.
ThefactorydefaultsettingisOFF.
7. Move the cursor to TIME OUT and then tilt the
joystick left and right to select the alarm signal
output time.
Tilting the joystick cycles through the output time
displayinthesequenceshownbelow.(unit:ms)
The factory default setting is 100MS.
8. Move the cursor to CNT-CLS 2, and then tilt the
joystick left and right to select the alarm output that
shouldbeperformedfromALARMOUT2whenan
alarm is detected.
OFF :Noalarmoutput
AUX2 :Output a contact close signal when
AUX2 input is received from the system
controller.
BW :Output a contact close signal only while
the camera is in the black and white
mode.
ThefactorydefaultsettingisOFF.
9. Move the cursor to COAX ALM OUT, and then tilt
thejoystickleftorrighttotoggleitONandOFF.
This setting turns alarm controls whether an alarm is
output when the camera moves to one of the preset
positionsspecifiedforALARMIN1through4(1POSI,
2POSI,3POSI,4POSI)insteps2through5,above.
ON :Output an alarm signal from the video
output connector at the point the camera
finishes moving to a preset position
(number1through4)whenthereisalarm
inputtoALARMIN(1through4).
OFF :Noalarmsignaloutput
ThefactorydefaultsettingisOFF.
Notes:
•The camera ignores alarm inputs during manual
operation.
•Turn offalarm outputswhen the system controller
downloads or uploads the preset data.
100 MS 200 MS 1000 MS 2000 MS 4000 MS