3 Rated Specifications (continuous)
Rated input voltage 415V
Model number YP-060PF YP-100PF
Spec. number YP-060PF3HJ YP-100PF3HJ
Rated input voltage V 415V AC (Allowable fluctuation range: ±20%)
Rated frequency Hz 50 / 60
No. of phase Three phase
Rated input
kVA
9.76(Cutting)
11.25(Gouging)
17.59(Cutting)
19.71(Gouging)
kW
7.19(Cutting)
8.37(Gouging)
13.72(Cutting)
15.78(Gouging)
Maximum non-load voltage V 295 295
Rated output current A 60 100
Rated output voltage V
104(Cutting)
124(Gouging)
120(Cutting)
140(Gouging)
Rated duty cycle % 100 60
Output current adjustable range A 15 60 15 100
Power control method IGBT inverter type
Cooling method Forced air-cooling
Insulation type
Main transformer 130℃(DCL 180℃)
IP code IP21S
EMC classification Class A
Dimensions (W x D x H) mm 290 × 606 × 559
Mass (Weight) kg 43 48

Table of Contents