28
045 Special Events
000
Power up after total power down 000 000
Software reset (Watchdog) 001 001
Test Report 002 002
Future Use 003 003
WinLoad In (connected) 004 004
WinLoad Out (disconnected) 005 005
Installer in programming 006 006
Installer out of programming 007 007
255 Any special event Not Used Not Used
046 Early to Arm by User
000 User Codes 001 to 255 001 to 255 001 to 255
001 User Codes 256 to 511 000 to 255 000 to 255
002 User Codes 512 to 767 000 to 255 000 to 255
003 User Codes 768 to 999 000 to 231 000 to 231
255 Any User Code Not Used Not Used
047 Late to Arm by User
000 User Codes 001 to 255 001 to 255 001 to 255
001 User Codes 256 to 511 000 to 255 000 to 255
002 User Codes 512 to 767 000 to 255 000 to 255
003 User Codes 768 to 999 000 to 231 000 to 231
255 Any User Code Not Used Not Used
048 Utility Key
000
Utility Key 001 to 064
†*
001 to 064 001 to 064
255
Any Utility Key
†*
Not Used Not Used
049 Request for Exit
000 Door numbers 001 to 032 001 to 032
255 Any door number Not Used Not Used
050 Access Denied
000 Door numbers 001 to 032 001 to 032
255 Any door number Not Used Not Used
051 Door Left Open Alarm
000 Door numbers 001 to 032 001 to 032
255 Any door number Not Used Not Used
052 Door Forced Alarm
000 Door numbers 001 to 032 001 to 032
255 Any door number Not Used Not Used
053 Door Left Open Restore
000 Door numbers 001 to 032 001 to 032
255 Any door number Not Used Not Used
054 Door Forced Open Restore
000 Door numbers 001 to 032 001 to 032
255 Any door number Not Used Not Used
055 Intellizone Triggered
000 Zone Numbers 001 to 192 001 to 192
255 Any zone number Not Used Not Used
056
Zone Excluded on Force
Arming
000 Zone Numbers 001 to 192 001 to 192
255 Any zone number Not Used Not Used
057
Zone Went Back to Arm
Status
000 Zone Numbers 001 to 192 001 to 192
255 Any zone number Not Used Not Used
058
New Module Assigned on
Combus
000 Module Numbers 001 to 254 001 to 254
255 Any moduel number Not Used Not Used
059
Module Manually Removed
From Combus
000 Module Numbers 001 to 254 001 to 254
255 Any moduel number Not Used Not Used
060 - 061
Future Use
Future Use Future Use Future Use Future Use
062 Access Granted to User
000 User Codes 001 to 255 001 to 255 001 to 255
001 User Codes 256 to 511 000 to 255 000 to 255
002 User Codes 512 to 767 000 to 255 000 to 255
003 User Codes 768 to 999 000 to 231 000 to 231
255 Any User Code Not Used Not Used
†: see page 29
*
: see page 29
Event
Group
Event Feature Group Feature Start # End #