NVX80 Installation Manual 17
3.7 Outputs
Outputs Sub-
Menu
Menu Item Description
Relay 1
Function
Form C relay / N.C. and N.O. terminal
outputs
Select events from a list to activate this relay
Relay 2
Function
Relay 2 is a solid state relay
Select events from a list to activate this relay
Relay 2
Logic
Select N.C. or N.O. (Remember: Relay 2 will open when
power is lost)
Relay 3
Function
Relay 3 is a solid state relay
Select events from a list to activate this relay
Relay 3
Logic
Select N.C. or N.O. (Remember: Relay 3 will open when
power is lost)
Relay Defaults
Relay 1 Relay 2 Relay 3
Alarm
Wall Tamper
IR
Anti-Mask
MW
Anti-Mask
PIR
Micr
owave
Clean Lens
Tro ub le
Creep Zone
NOTE: Using Relay 1 (form C) provides a higher safety level, as an indication may be generated on power loss (line
cut). It should be noted that this feature increases power consumption.