SP+ Series Programming Guide
27
User Programming
Use the following section to program the various user features on your SP+ Series control panel.
System Codes
Use worksheet 18 to record your settings for the SP+ system codes. For access options, see section [701], in table 24 on page 36.
NOTE: The maintenance code cannot access the following sections: [395] (Installer code lock); [397] (Installer code); [398] (Maintenance code); [815] (Monitoring
station telephone number 1); [816] (Monitoring station telephone number 2); [817] (Backup monitoring station telephone); [910] (Panel ID); [911] (PC password);
[970] (Download memory key into panel); [975] (Upload panel into the memory key).
NOTE: The installer and system master codes may consist of four (default) or six digits (see option 1 of section [701], in table 24 on page 36). The control panel
automatically removes the last two digits of these codes, if the length is changed from six digits to four. However, if the access code length is changed from four
digits to six, the control panel adds the code’s first two digits to the end of the code.
User Code Options
Use worksheet 19 to record your settings for the SP+ Series user code options. See table 15 for details on these options.
NOTE: When section [400] is accessed, the control panel will copy the saved value of that section to all user option sections ([404] to [432]).
NOTE: The system master, master 1, and master 2 user code options cannot be modified. However, if partitioning is not enabled, the user code options for master 2
will match those of master 1.
Worksheet 18: User System Codes
Section Data Description Default Setting
[395] ___/___/___ Installer code lock* 000
[397] ___/___/___/___/___/___ Installer code 0000
[398] ___/___/___/___/___/___ Maintenance code -
[399] ___/___/___/___/___/___ System master code 1234
* Enter 147 to lock entire control panel. Once locked, enter any other three-digit combination to unlock.
Table 15: User code options
Option
Description
1 Partition 1 access
2 Partition 2 access
3 Bypass programming
4 Stay/Sleep arming
5Force arming
6Arm only
7 PGM activation only
8Duress
Worksheet 19: User Code Options
Section User Options Section User Options
[400] Default option 12345678 [417] User 17 12345678
[401] System master 12345678 [418] User 18 12345678
[402] Master 1 12345678 [419] User 19 12345678
[403] Master 2 12345678 [420] User 20 12345678
[404] User 4 12345678 [421] User 21 12345678
[405] User 5 12345678 [422] User 22 12345678
[406] User 6 12345678 [423] User 23 12345678
[407] User 7 12345678 [424] User 24 12345678
[408] User 8 12345678 [425] User 25 12345678
[409] User 9 12345678 [426] User 26 12345678
[410] User 10 12345678 [427] User 27 12345678
[411] User 11 12345678 [428] User 28 12345678
[412] User 12 12345678 [429] User 29 12345678
[413] User 13 12345678 [430] User 30 12345678
[414] User 14 12345678 [431] User 31 12345678
[415] User 15 12345678 [432] User 32 12345678
[416] User 16 12345678

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Paradox SP5500+ and is the answer not in the manual?

Paradox SP5500+ Specifications

General IconGeneral
StayD ModeYes
PGMs4 programmable outputs
Partitions2 partitions
Expandable via BusYes
Outputs4 programmable outputs
Power Supply1.5A
Battery Backup7Ah