EasyManuals Logo

Paradox SP5500+ User Manual

Paradox SP5500+
68 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #50 background imageLoading...
Page #50 background image
50
SP+ Series Programming Guide
Communication Report Codes
Use worksheet 45 to record your settings for communication report codes. Sections [879] and [884] apply to network GPRS communications. See Communication
Programming on page 41, for more communication features. In addition, refer to Description of Sections [966] and [967] on page 53, for clearing and resetting codes.
Communication Restore Report Codes
Use worksheet 46 to record your settings for communication restore report codes. Section [881] applies to network GPRS communications.
Software Options and Additional Timers
Use the following section to program software options and additional communication timers on your SP+ control panel.
Additional Communication Timers
Use worksheet 47 to record your settings for sections [901] and [902]. For additional timers, see worksheets 38 and 39.
RF zone supervision lost 1 381 Loss of supervision - RF US Untype zone supervision
RF zone supervision restore 3 381 Supervision restore - RF UR Untyped zone restoral
RF module supervision lost 1 381 Loss of supervision - RF US Untyped zone supervision
RF module supervision restore 3 381 Loss of supervision - RF restore UR Untyped zone restoral
RF module tamper 1 145 Expansion module tamper ES Expansion device tamper
RF module tamper restore 3 145 Expansion module tamper restore EJ Expansion device restore
Paramedic alarm 1 1AA Medical MA Medical alarm
Zone forced 1 57A Zone forced XW Zone forced
Zone included 3 57A Zone included UU Zone included
Remote low battery 1 338 Battery failure on module YT Module battery fail
Remote low battery restore 3 338 Battery failure on module restore YR Module battery fail restore
Failed to arm 1 454 Failed to close CI Failed to close
Worksheet 45: Communication Report Codes
Section Data Description Section Data Description Section Data Description
[879]
___/___ PCS series RF jam
[880]
___/___ -
[884]
___/___
N/A
___/___ PCS series no service ___/___ IP Module no service ___/___ -
___/___
PCS series module
supervision lost
___/___ IP Module supervision lost ___/___ -
___/___
Receiver fail to
communicate (GPRS)
___/___
IP receiver fail to
communicate
___/___ -
Worksheet 46: Communication Restore Report Codes
Section Data Description Section Data Description
[881]
___/___ PCS series RF jam
[882]
___/___ -
___/___ PCS series no service ___/___ IP Module no service
___/___ PCS series module supervision lost ___/___ IP Module supervision lost
___/___ Receiver fail to communicate (GPRS) ___/___ IP receiver fail to communicate
Table 43: Description of section [900] (BabyWare options)
Section Option Description OFF ON
[900]
1Call back Disabled
Enabled
2 Automatic event buffer transmission Disabled
Enabled
= Default
Worksheet 47: Additional Communication Timers
Section Data Description Default
[901] ___/___/___ 000 to 255 rings Number of rings 008
[902] ___/___/___ 000 to 255 secs. (max 127) Answering machine override delay 030
Table 42: List of automatic report codes (Continued)
System Event Default Contact ID Report Code Default SIA Report Code

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Paradox SP5500+ and is the answer not in the manual?

Paradox SP5500+ Specifications

General IconGeneral
StayD ModeYes
PGMs4 programmable outputs
Partitions2 partitions
Expandable via BusYes
Outputs4 programmable outputs
Power Supply1.5A
Battery Backup7Ah

Related product manuals