SP+ Series Programming Guide
Keypad Lockout
Use the following section to program keypad lockout settings for your SP+ control panel. Use worksheet 30 to record your settings.
NOTE: For EN 50131, the keypad lockout value must be set between three and ten attempts. The minimum delay to lock must be two minutes.
Dialer Options
Timers
Use worksheet 38 to record your settings for sections [820] to [840].
[715] ___/___/___ 000 to 255
Recycle alarm counter
(default: 000) [723] ___/___/___ 000 to 255 seconds
Panic shutdown**
(default: 010)
* For EN 50131, the maximum value is 45 seconds.
** For EN 50131, the section must be set to a minimum of 3 and a maximum of 10
Worksheet 55: Keypad Lockout
Section Data Description Default
[716] ___/___/___ 000 to 255 minutes Keypad lockout delay 015 minutes
[717] ___/___/___ 000 to 255 attempts before locking Keypad lockout counter 005 attempts
Table 59: Description of section [801]
Option Description OFF ON
Section [801]
1 Report system disarming
Always After alarm
2 Report zone restore on closure
Bell cutoff Zone closure
3 & 4 Auto-test report transmission Disabled
Enabled
5Contact ID override Disabled
Enabled
6 Future use
7 Future use
8 Future use
= Default
Worksheet 56: Communication Timers
Section Data Description Default
[820] ___/___/___ 000 to 255 hours Fail to comm. clear event timer 000 = disabled
[830] ___/___/___ 000 to 255 x 2 seconds TLM fail delay (landline only) 016
[831] ___/___/___ 000 to 032 Maximum dialing attempts monitoring station (landline only) 002
[832] ___/___/___ 000 to 127 seconds Delay between dialing attempts* (landline only) 020
[833] ___/___/___ 000 to 255 seconds Delay alarm transmission 000
[838] ___/___/___ 000 to 255 seconds Recent closing delay 000
[839] ___/___/___ 000 to 255 minutes Power failure report delay** 015
[840] ___/___/___ 000 to 255 days Auto test report (see table 36 on page 41) 001
* Also applicable when using a VDMP3 Plug-in Voice Dialer.s
**The maximum value for power failure is 60 minutes.
Worksheet 54: System Timers
Section Data Description Section Data Description

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Paradox SP5500+ and is the answer not in the manual?