44
SP+ Series Programming Guide
Test Report and Report Delays
Use worksheet 39 to record your settings for sections [850] to [852]. For additional timers, see worksheets 38 and 47 on pages 43 and 50, respectively.
System and Communication Report Codes
Use the following section to program system report codes, as well as additional communication report codes on your SP+ control panel.
Entering Report Codes
• For Ademco slow, Silent Knight, SESCOA, and Ademco express formats, key-in the desired two-digit hex value from 00 to FF.
• For Ademco Programmable Format, enter the desired two-digit hex value, found in table 41 on page 46. Entering FF will set the report code to those
outlined in table 42 on page 48.
• For Ademco All Codes Format, the control panel automatically generates report codes from the ones found in table 42 on page 48.
Special Arming and Disarming Report Codes
Use worksheet 40 to record your settings for special arming and disarming report codes.
Special Alarm Report Codes
Use worksheet 41 to record your settings for special alarm report codes.
Worksheet 39: Test Report and Report Delays
Section Data Description Default
[850] ___/___/___ HH:MM Auto test report time of day (see table 36 on page 41) 00:00
[851] ___/___/___ 000 to 255 minutes Armed report delay 005
[852] ___/___/___ 000 to 255 minutes Disarmed report delay 060
Worksheet 40: Special Arming and Disarming Report Codes
Section Data Description Section Data Description Section Data Description
[860]
___/___ Auto-arming
[861]
___/___ Quick arming
[862]
___/___ Cancel auto-arm
___/___ Late to close ___/___ Arming via PC ___/___ Disarming via PC
___/___ No movement ___/___ Arming with keyswitch ___/___
Cancel alarm with user or
BabyWare
___/___ Partial arming ___/___ - ___/___ Cancel paramedic
Default: FF
Worksheet 41: Special Alarm Report Codes
Section Data Description Section Data Description
[863]
___/___ Emergency panic
[864]
___/___ Zone shutdown
___/___ Auxiliary panic ___/___ Duress
___/___ Fire panic ___/___ Keypad lockout
___/___ Recent closing ___/___ Paramedic alarm
Default: FF