18 Programming Guide
Event Description
Event Group # Sub-group #
00 = Zone OK
01 to 32 = Zone number
99 = Any zone number
01 = Zone open
02 = Partition status 00 to 01= N/A
02 = Silent alarm
03 = Buzzer alarm
04 = Steady alarm
05 = Pulsed alarm
06 = Strobe
07 = Alarm stopped
08 = Squawk ON (Partition 1 only)
09 = Squawk OFF (Partition 1 only)
10 = Ground start (Partition 1 only)
11 = Disarm partition
12 = Arm partition
13 = Entry delay started
14 = Exit delay started
15 = Pre-alarm delay
99 = Any partition status event
03 = Bell status (Partition 1 only) 00 = Bell OFF
01 = Bell ON
02 = Bell squawk arm
03 = Bell squawk disarm
99 = Any bell status event
06 = Non-reportable event 00 = Telephone line trouble
01 = [
ENTER] / [CLEAR] / [ ] key was pressed (Partition 1 only)
02 = N/A
03 = Arm in stay mode
04 = Arm in sleep mode
05 = Arm in force mode
06 = Full arm when armed in stay mode
07 = PC fail to communicate (Partition 1 only)
08 = Utility Key 1 pressed (keys [1] and [2]) (Partition 1 only)
09 = Utility Key 2 pressed (keys [2] and [3]) (Partition 1 only)
10 = Utility Key 3 pressed (keys [4] and [5]) (Partition 1 only)
11 = Utility Key 4 pressed (keys [5] and [6]) (Partition 1 only)
12 = Utility Key 5 pressed (keys [7] and [8]) (Partition 1 only)
13 = Utility Key 6 pressed (keys [8] and [9]) (Partition 1 only)
14 = Tamper generated alarm
15 = Supervision loss generated alarm
16 = N/A
17 = N/A
18 = N/A
19 = N/A
20 = Full arm when armed in sleep mode
21 = Firmware upgrade (Partition 1 only)
99 = Any non-reportable event
07 = Remote control access 01 to 32 = Remote control number
99 = Any remote control number
08 = Button pressed on remote
(See button option “B” on page 26)
09 = Button pressed on remote
(See button option “C” on page 26)
10 = Button pressed on remote
(See button option “D” on page 26)
11 = Button pressed on remote
(See button option “E” on page 26)
12 = Cold start wireless zone 01 to 32 = Zone number
99 = Any zone number

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Paradox SPECTRA SP5500 and is the answer not in the manual?

Paradox SPECTRA SP5500 Specifications

General IconGeneral
Partitions2
User Codes32
Event Buffer256 events
StayD ModeYes
CommunicationGSM (optional)
Remote ControlYes
System TypeHybrid
Wireless Zones32
Battery Backup12V 7Ah
Operating Temperature0°C to 50°C (32°F to 122°F)
Humidity5% to 90% non-condensing