Magellan / Spectra SP 35
System Programming
[700] General System Options Bold = Default setting
Option OFF ON
[1]
Partitioning
N Disabled N Enabled
[2]
Battery charging (350mA or 700mA)
N 350mA N 700mA
[3]
Audible trouble warning (except AC failure)
N Disabled N Enabled
[4]
Audible trouble warning on AC failure
N Disabled N Enabled
[5]
RF jamming supervision
N Disabled N Enabled
[6]
Exit delay termination
N Disabled N Enabled
[7]
Tamper supervision on the bus module
N Disabled N Enabled
[8] N/A N/A N/A
[701] General Code Options Bold = Default setting
Option OFF ON
[1]
Access code length
N 6 digits N 4 digits
[2]
Lock master code
N Disabled N Enabled
[3]
Confidential mode
N Disabled N Enabled
[4]
To exit confidential mode
N Enter a code N Press a key
[5]
Confidential mode timer
N 2 minutes N 5 seconds
[6]
MG-REM2 version number
N MG-REM2 V2.00 N MG-REM2 V2.01 or higher
[7]
Display entry delay on LCD keypad (MG32LCD)
N Disabled N Enabled
[8]
Display exit delay on LCD keypad (MG32LCD)
N Disabled N Enabled
[702] Panic Options Bold = Default setting
Option OFF ON
[1]
Panic 1
N Disabled N Enabled
[2]
Panic 2
N Disabled N Enabled
[3]
Panic 3
N Disabled N Enabled
[4]
Panic 1: Silent or audible alarm
N Silent N Audible
[5]
Panic 2: Silent or audible alarm
N Silent N Audible
[6]
Panic 3: Silent or audible alarm
N Silent N Audible
[7] & [8] N/A N/A N/A
[703] Arming/Disarming Options 1 Bold = Default setting
Option OFF ON
[1]
One-touch regular/force arming
N Disabled N Enabled
[2]
One-touch stay arming
N Disabled N Enabled
[3]
One-touch sleep arming
N Disabled N Enabled
[4]
One-touch bypass programming
N Disabled N Enabled
[5]
Restrict arming on battery failure
N Disabled N Enabled
[6]
Restrict arming on tamper failure (Zone + Bus Module
+ Wireless PGM)
N Disabled N Enabled
[7] Restrict arming on wireless supervision trouble (Zone + Bus
Module + Wireless PGM)
N Disabled N Enabled
[8]
Arm/Disarm with VDMP3
N Disabled N Enabled