[700] General System Options Bold = Default setting
Option OFF ON
[1]
Partitioning
N Disabled N Enabled
[2]
Battery charging (350mA or 700mA)
N 350mA N 700mA
[3]
Audible trouble warning (except AC failure)
N Disabled N Enabled
[4]
Audible trouble warning on AC failure
N Disabled N Enabled
[5]
RF jamming supervision
N Disabled N Enabled
[6]
Exit delay termination
N Disabled N Enabled
[7]
Tamper supervision on the bus module
N Disabled N Enabled
[8] N/A N/A N/A
[701] General Code Options Bold = Default setting
Option OFF ON
[1]
Access code length
N 6 digits N 4 digits
[2]
Lock master code
N Disabled N Enabled
[3]
Confidential mode
N Disabled N Enabled
[4]
To exit confidential mode
N Enter a code N Press a key
[5]
Confidential mode timer
N 2 minutes N 5 seconds
[6]
MG-REM2 version number
N MG-REM2 V2.00 N MG-REM2 V2.01 or higher
[7]
Display entry delay on LCD keypad (MG32LCD)
N Disabled N Enabled
[8]
Display exit delay on LCD keypad (MG32LCD)
N Disabled N Enabled
[702] Panic Options Bold = Default setting
Option OFF ON
[1]
Panic 1
N Disabled N Enabled
[2]
Panic 2
N Disabled N Enabled
[3]
Panic 3
N Disabled N Enabled
[4]
Panic 1: Silent or audible alarm
N Silent N Audible
[5]
Panic 2: Silent or audible alarm
N Silent N Audible
[6]
Panic 3: Silent or audible alarm
N Silent N Audible
[7] & [8] N/A N/A N/A
[703] Arming/Disarming Options 1 Bold = Default setting
Option OFF ON
[1]
One-touch regular/force arming
N Disabled N Enabled
[2]
One-touch stay arming
N Disabled N Enabled
[3]
One-touch sleep arming
N Disabled N Enabled
[4]
One-touch bypass programming
N Disabled N Enabled
[5]
Restrict arming on battery failure
N Disabled N Enabled
[6]
Restrict arming on tamper failure (Zone + Bus Module
+ Wireless PGM)
N Disabled N Enabled
[7] Restrict arming on wireless supervision trouble (Zone + Bus
Module + Wireless PGM)
N Disabled N Enabled
[8]
Arm/Disarm with VDMP3
N Disabled N Enabled

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Paradox SPECTRA SP5500 and is the answer not in the manual?

Paradox SPECTRA SP5500 Specifications

General IconGeneral
Partitions2
User Codes32
Event Buffer256 events
StayD ModeYes
CommunicationGSM (optional)
Remote ControlYes
System TypeHybrid
Wireless Zones32
Battery Backup12V 7Ah
Operating Temperature0°C to 50°C (32°F to 122°F)
Humidity5% to 90% non-condensing