36 Programming Guide
[704] Arming/Disarming Options 2 Bold = Default setting
Option OFF ON
[1]
Regular arming switches to force arming
N Disabled N Enabled
[2]
Stay arming switches to stay force arming
N Disabled N Enabled
[3]
Sleep arming switches to sleep force arming
N Disabled N Enabled
[4]
Bell squawk when arm/disarm with remote
N Disabled N Enabled
[5]
Bell squawk when arm/disarm with a keypad
N Disabled N Enabled
[6]
Beep on exit delay
N Disabled N Enabled
[7] No exit delay beeps and no bell squawk when stay/sleep
arm
N Disabled N Enabled
[8]
No exit delay when arm with a remote
N Disabled N Enabled
[705] General Zone Options 1 Bold = Default setting
Option OFF ON
[1]
ATZ zone doubling
N Disabled N Enabled
[2]
ATZ wiring options
N Series N Parallel
[3] & [4] Tamper Recognition
[5]
Generate tamper on bypassed zone
N No N Yes
[6] & [7] Supervision Options
[8]
Generate supervision on bypassed zone
N No N Yes
[706] General Zone Options 2 Bold = Default setting
Option OFF ON
[1]
Check-in supervision time
N 24 hours N 80 minutes
[2]
EOL resistors
N Disabled N Enabled
[3]
Zone Input 1 becomes a 2-wire smoke input (except SP5500)
N Disabled N Enabled
[4]
ZX8 ID A (Panel + 1) Input 1
N Zone input N Tamper input
[5]
ZX8 ID B (Panel + 9) Input 1
N Zone input N Tamper input
[6]
ZX8 ID C (Panel + 17) Input 1
N Zone input N Tamper input
[4] to [8] N/A N/A N/A
[3] [4]
RF Zone Tamper Recognition Options Keypad Bus / RF Module Tamper Recognition Options*
OFF OFF Disabled Disabled
OFF ON
TROUBLE ONLY TROUBLE ONLY
ON OFF When disarmed: TROUBLE ONLY
When armed: Follow zone’s alarm type
TROUBLE ONLY
ON ON When disarmed: AUDIBLE ALARM
When armed: Follow zone’s alarm type
AUDIBLE ALARM
* Tamper recognition of keypad / bus module only if section [700] option [7] is enabled.
[6] [7]
RF Zone Supervision Options Keypad Bus / RF Module Supervision Options
OFF OFF Disabled Disabled
OFF ON
TROUBLE ONLY TROUBLE ONLY
ON OFF When disarmed: TROUBLE ONLY
When armed: Follow zone’s alarm type
TROUBLE ONLY
ON ON When disarmed: AUDIBLE ALARM
When armed: Follow zone’s alarm type
AUDIBLE ALARM

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Paradox SPECTRA SP5500 and is the answer not in the manual?

Paradox SPECTRA SP5500 Specifications

General IconGeneral
Partitions2
User Codes32
Event Buffer256 events
StayD ModeYes
CommunicationGSM (optional)
Remote ControlYes
System TypeHybrid
Wireless Zones32
Battery Backup12V 7Ah
Operating Temperature0°C to 50°C (32°F to 122°F)
Humidity5% to 90% non-condensing

Related product manuals