Magellan / Spectra SP 39
Communication Programming
[800] Dialer Options Bold = Default setting
Option OFF ON
[1] & [2]
N See Table N See Table
[3]
Switch to pulse on 5
th
attempt
N Disabled N Enabled
[4] Alternate dial
N Disabled N Enabled
[5] Force dial (must be enabled to comply with TBR-21)
N Disabled N Enabled
[6] DTMF dialing
N Disabled N Enabled
[7]
Pulse ratio
N1:2 N 1:1.5
[8] Disable test reporting
N Disabled N Enabled
[801] Dialer Options Bold = Default setting
Option OFF ON
[1] Report system disarming
N Always N After alarm
[2] Report zone restore
N Bell cutoff N Zone closure
[3] & [4]
[5] to [8] N/A N/A N/A
[802] Event Call Direction Options 1 Bold = Default setting
Option OFF ON
[1] Call tel. #1 for arm/disarm reporting codes
N Disabled N Enabled
[2] Call tel. #2 for arm/disarm reporting codes
N Disabled N Enabled
[3] Call pager for arm/disarm reporting codes
N Disabled N Enabled
[4] N/A N/A N/A
[5] Call tel. #1 for alarm/restore reporting codes
N Disabled N Enabled
[6] Call tel. #2 for alarm/restore reporting codes
N Disabled N Enabled
[7]
Call pager for alarm/restore reporting codes
N Disabled N Enabled
[8] N/A N/A N/A
Telephone Line Monitoring (TLM) Options
[1] [2]
OFF OFF Disabled
OFF ON When disarmed: Trouble only
When armed: Trouble only
ON OFF When disarmed: Trouble only
When armed: Audible alarm
ON ON Silent alarms become Audible alarm
[3] [4] Auto-Test Report Transmission Options
OFF OFF Transmit the test report code every time the days programmed in section [840] have elapsed at the time programmed in
section [850] (default).
OFF ON When disarmed: Transmit test report code every time the time programmed in section [852] has elapsed. When armed:
Transmit test report code every time the time programmed in section [851] has elapsed.
ON OFF The control panel will transmit the test report code every hour on the minute value programmed in section [850] (the last
two digits). Note that the first two digits of section [850] will be ignored. E.g. If 10:25 was programmed into section [850],
the test report code would be transmitted at the 25th minute of every hour, i.e. 11:25, 12:25, etc.
ON ON The test report code will be transmitted when any of the conditions of the second and third options listed above (options
[3] = OFF and [4] = ON / options [3] = ON and [4] = OFF) are met.