20 Programming Guide
35 = Zone bypassed 01 to 32 = Zone number
99 = Any zone number
36 = Zone in alarm
37 = Fire alarm
38 = Zone alarm restore
39 = Fire alarm restore
40 = Special alarm 00 = Panic non-medical emergency
01 = Panic medical (this panic alarm is not UL approved)
02 = Panic fire
03 = Recent closing
04 = Global shutdown
05 = Duress alarm
06 = Keypad lockout (Partition 1 only)
99 = Any special alarm event
41 = Zone shutdown 01 to 32 = Zone number
99 = Any zone number
42 = Zone tampered
43 = Zone tamper restore
44 = New trouble
(Partition 1 only except sub-group 07 = both partitions)
00 = N/A
01 = AC failure
02 = Battery failure
03 = Auxiliary current overload
04 = Bell current overload
05 = Bell disconnected
06 = Clock loss
07 = Fire loop trouble
08 = Fail to communicate to monitoring station telephone #1
09 = Fail to communicate to monitoring station telephone #2
10 = Fail to communicate to pager report
11 = Fail to communicate to voice report
12 = RF interference
99 = Any new trouble event
45 = Trouble restored 00 = Telephone line restored
01 = AC failure restore
02 = Battery failure restore
03 = Auxiliary current overload restore
04 = Bell current overload restore
05 = Bell disconnected restore
06 = Clock loss restore
07 = Fire loop trouble restore
12 = RF interference restore
99 = Any trouble restored event
46 = Bus/wireless module new trouble (Partition 1 only) 00 = Bus communication fault
01 = Tamper trouble
02 = Power fail
03 = Battery failure
99 = Any bus module new trouble event
47 = Bus/wireless module trouble restored (Partition 1 only) 00 = Bus communication fault restore
01 = Tamper trouble restore
02 = Power fail
03 = Battery failure
99 = Any bus module trouble restored event
Event Group # Sub-group #