Programming D-46
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D
Parameter Descriptions
This parameter changes according to the CONTROL MODE (DRIVE CONFIG function block):
• In CLOSED-LOOP VEC mode the parameter shows the mechanical speed of the motor shaft in revolutions per minute as
calculated from the speed feedback device.
• In SENSORLESS VEC mode the parameter shows the calculated mechanical speed of the motor shaft in revolutions per
minute.
• In VOLTS/Hz mode the parameter shows motor synchronous speed in rpm.
• In PMAC control mode, the parameter shows the mechanical speed of the motor shaft.
This parameter changes according to the CONTROL MODE (DRIVE CONFIG function block):
• In CLOSED-LOOP VEC mode the parameter shows the mechanical speed of the motor shaft in revolutions per second as
calculated from the motor speed feedback.
• In SENSORLESS VEC mode the parameter shows the calculated mechanical speed of the motor shaft in revolutions per
second.
• In VOLTS / Hz mode, the parameter shows the motor synchronous speed in revolutions per second.
• In PMAC control mode, the parameter shows the mechanical speed of the motor shaft.