Programming D-138
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D
0.3
0.15 to 1.0
Set the resolver’s transformation ratio (at 8kHz, nominal carrier voltage).
Set the resolver’s maximum mechanical speed in RPM. If unknown, the value must be set to the motor maximum speed.
Range: 0.00 to 60.00 minutes
Set the resolver’s peak to peak accuracy (in minutes). If unknown, use the default value.
1.00 to 10.00V
Set the resolver’s nominal carrier rms voltage at 8kHz (in Volts). If unknown, use the default value.
07
Set the resolver’s nominal carrier rms current at 8kz under nominal carrier voltage (in Amps). If unknown, use the default value.
32768.00Kg.cm2
Set the resolver’s rotor inertia (in kg*cm²). If unknown, use the default value.
-180.00 to 180.00 deg
The electrical position offset value, in degrees. The value will adapt the resolver to the motor phasing (this parameter is
automatically set up by using the MOT POLARISATION function block). The value could also be entered here if known.
Mechanical position given by the resolver.
SE
This is a diagnostic output indicating a resolver trip:
TRIP = FALSE : resolver is OK
TRIP = TRUE : resolver is tripped