D-139
Programming
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D
Parameter Descriptions
INIT DONE
PREF: 133.17
Default: TRUE
Range: FALSE / TRUE
This is a diagnostic output indicating the state of
the resolver init sequence:
INIT DONE = FALSE : init on going
INIT DONE = TRUE : init done
REVERSE CNT DIR
PREF: 133.18
Default: FALSE
Range: FALSE / TRUE
Set the count direction for the resolver feedback.
REVERSE CNT DIR = FALSE : the position is incre
asing if the motor is running in a clockwise direction looking to the front
shaft of the motor.
REVERSE CNT DIR = TRUE : the position is decreasing if the motor is running in a clockwise direction looking to the front
shaft of the motor.
SPEED FILTER
PREF
: 133.19
Default: 100.00
Range: 10.00 to 1000.00 Hz