EasyManua.ls Logo

Parker ac890 - Page 629

Parker ac890
711 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
D-233
Programming
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D
2PREF Name Block Type Range Default ro\rw Notes
99.06 BRAKING DYNAMIC
BRAKING
BOOL 0 : FALSE
1 : TRUE
FALSE ro Output
99.07 INT DB RESISTOR DYNAMIC
BRAKING
BOOL 0 : FALSE
1 : TRUE
FALSE rw 3
100.01 RAMP TYPE REFERENCE
RAMP
ENUM 0 : LINEAR
1 : S
LINEAR rw
100.02 ACCEL TIME REFERENCE
RAMP
REAL 0.0 to 3000.0 s 20.0 s rw 3
100.03 DECEL TIME REFERENCE
RAMP
REAL 0.0 to 3000.0 s 20.0 s rw 3
100.04 SYMMETRIC MODE REFERENCE
RAMP
BOOL 0 : FALSE
1 : TRUE
FALSE rw
100.05 SYMMETRIC TIME REFERENCE
RAMP
REAL 0.0 to 3000.0 s 20.0 s rw 3
100.06 SRAMP
CONTINUOUS
REFERENCE
RAMP
BOOL 0 : FALSE
1 : TRUE
TRUE rw
100.07 SRAMP ACCEL REFERENCE
RAMP
REAL 0.00 to 100.00 /s^2 10.00 /s^2 rw
100.08 SRAMP DECEL REFERENCE
RAMP
REAL 0.00 to 100.00 /s^2 10.00 /s^2 rw
100.09 SRAMP JERK 1 REFERENCE
RAMP
REAL 0.00 to 100.00 /s^3 10.00 /s^3 rw
100.10 SRAMP JERK 2 REFERENCE
RAMP
REAL 0.00 to 100.00 /s^3 10.00 /s^3 rw
100.11 SRAMP JERK 3 REFERENCE
RAMP
REAL 0.00 to 100.00 /s^3 10.00 /s^3 rw
100.12 SRAMP JERK 4 REFERENCE
RAMP
REAL 0.00 to 100.00 /s^3 10.00 /s^3 rw
100.13 HOLD REFERENCE
RAMP
BOOL 0 : FALSE
1 : TRUE
FALSE rw

Table of Contents