Programming D-234
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D
2PREF Name Block Type Range Default ro\rw Notes
100.14 RAMPING REFERENCE
RAMP
BOOL 0 : FALSE
1 : TRUE
FALSE ro Output
101.01 REMOTE
SETPOINT
REFERENCE REAL -300.00 to 300.00 % 0.00 % rw
101.02 SPEED TRIM REFERENCE REAL -300.00 to 300.00 % 0.00 % rw
101.03 MAX SPEED
CLAMP
REFERENCE REAL 0.00 to 110.00 % 110.00 % rw
101.04 MIN SPEED CLAMP REFERENCE REAL -110.00 to 0.00 % -110.00 % rw
101.05 TRIM IN LOCAL REFERENCE BOOL 0 : FALSE
1 : TRUE
FALSE rw
101.06 REMOTE REVERSE REFERENCE BOOL 0 : FALSE
1 : TRUE
FALSE rw
101.07 COMMS SETPOINT REFERENCE REAL -300.00 to 300.00 % 0.00 % rw 1
101.08 MAX SPEED REFERENCE REAL 0 to 32000 RPM 1500 RPM rw 4
101.09 SPEED DEMAND REFERENCE REAL _.xx 0.00 % ro Output
101.10 SPEED SETPOINT REFERENCE REAL _.xx 0.00 % ro Output
101.11 REVERSE REFERENCE BOOL 0 : FALSE
1 : TRUE
FALSE ro Output
101.12 LOCAL SETPOINT REFERENCE REAL _.xx 0.00 % ro Output
101.13 LOCAL REVERSE REFERENCE BOOL 0 : FALSE
1 : TRUE
FALSE ro Output
101.15 FWIRE SETPOINT REFERENCE REAL _.xx 0.00 % ro Output
101.16 SPEED DEMAND REFERENCE REAL _.x 0.0 Hz ro Output
102.01 RUN STOP MODE REFERENCE
STOP
ENUM 0 : RUN RAMP
1 : COAST
2 : DC INJECTION
3 : STOP RAMP
RUN RAMP rw
102.02 STOP TIME REFERENCE
STOP
REAL 0.0 to 600.0 s 10.0 s rw