D-235
Programming
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D
2PREF Name Block Type Range Default ro\rw Notes
102.03 STOP ZERO
SPEED
REFERENCE
STOP
REAL 0.00 to 100.00 % 0.10 % rw
102.04 STOP DELAY REFERENCE
STOP
REAL 0.000 to 30.000 s 0.500 s rw
102.05 FAST STOP MODE REFERENCE
STOP
ENUM 0 : RAMP
1 : COAST
RAMP rw
102.06 FAST STOP LIMIT REFERENCE
STOP
REAL 0.0 to 3000.0 s 30.0 s rw
102.07 FAST STOP TIME REFERENCE
STOP
REAL 0.0 to 600.0 s 0.1 s rw
102.08 FINAL STOP RATE REFERENCE
STOP
REAL 1 to 4800 Hz/s 1200 Hz/s rw
103.01 SETPOINT REFERENCE JOG REAL -100.00 to 100.00 % 10.00 % rw
103.02 ACCEL TIME REFERENCE JOG REAL 0.0 to 3000.0 s 1.0 s rw
103.03 DECEL TIME REFERENCE JOG REAL 0.0 to 3000.0 s 1.0 s rw
105.01 STALL TIME STALL TRIP REAL 0.1 to 3000.0 s 480.0 s rw 3
105.03 STALL LIMIT TYPE STALL TRIP ENUM 0 : TORQUE
1 : CURRENT
2 : TRQ OR CURRENT
TRQ OR CURRENT rw
108.01 ADVANCE PHASE INCH BOOL 0 : FALSE
1 : TRUE
FALSE rw
108.02 RETARD PHASE INCH BOOL 0 : FALSE
1 : TRUE
FALSE rw
108.03 RATE PHASE INCH REAL 0.0001 to 30.0000 0.1000 rw
108.04 ACTIVE PHASE INCH BOOL 0 : FALSE
1 : TRUE
FALSE ro Output
108.08 RATE SCALE PHASE INCH REAL 0.001 to 30.000 1.000 rw
108.09 RESET PHASE INCH BOOL 0 : FALSE
1 : TRUE
FALSE rw