EasyManua.ls Logo

Parker ac890 - Page 653

Parker ac890
711 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
D-257
Programming
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D
2PREF Name Block Type Range Default ro\rw Notes
161.03 I2T MOTOR LOAD MOT PMAC
PROTECT
REAL _.x 0.0 % ro Output
161.04 MOTOR I2T TRIP MOT PMAC
PROTECT
BOOL 0 : FALSE
1 : TRUE
FALSE ro Output
161.05 ENABLE MOT PMAC
PROTECT
BOOL 0 : FALSE
1 : TRUE
TRUE rw
162.01 AIMING POINT INVERS TIME
PMAC
REAL 25.00 to 105.00 % 105.00 % rw
162.02 DELAY INVERS TIME
PMAC
REAL 0.5 to 60.0 s 4.0 s rw
162.03 DOWN TIME INVERS TIME
PMAC
REAL 0.5 to 10.0 s 1.0 s rw
162.04 UP TIME INVERS TIME
PMAC
REAL 0.5 to 10.0 s 1.0 s rw
162.05 IT LIMITING INVERS TIME
PMAC
BOOL 0 : FALSE
1 : TRUE
FALSE ro Output
162.06 INVERSE TIME OP INVERS TIME
PMAC
REAL _.xx 0.00 % ro Output
162.07 IT WARNING INVERS TIME
PMAC
BOOL 0 : FALSE
1 : TRUE
FALSE ro Output
163.01 SELECT TQ COMP
2
SPEED LOOP 2 ENUM 0 : NONE
1 : MAX ATTENUATION
2 : MINIMUM PHASE
3 : NOTCH FILTER
NONE rw 2
163.02 TQ COMP 2 FREQ SPEED LOOP 2 REAL 100 to 8000 Hz 2000 Hz rw
163.03 SELECT TQ COMP
3
SPEED LOOP 2 ENUM 0 : NONE
1 : MAX ATTENUATION
2 : MINIMUM PHASE
3 : NOTCH FILTER
NONE rw 2
163.04 TQ COMP 3 FREQ SPEED LOOP 2 REAL 100 to 8000 Hz 2000 Hz rw

Table of Contents

Other manuals for Parker ac890