Programming D-260
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D
2PREF Name Block Type Range Default ro\rw Notes
177.08 MAC ADDRESS ETHERNET STRING max length is 15 chars ro Output
177.09 NETWORK TYPE ETHERNET ENUM 0 : NONE
1 : UNKNOWN
2 : ETHERNET IP
3 : MODBUS TCP
4 : PROFINET IO
5 : ETHERCAT
NONE ro Output
178.01 PHYSICAL ADDR PEER TO PEER INT _ 0 ro Output
178.02 NET ADDR PEER TO PEER INT _ 0 ro Output
178.03 STATUS PEER TO PEER ENUM 0 : UNKNOWN
1 : ERROR
2 : DUP PHY ADDR
3 : INITIALISING
4 : NO BUS
5 : NO MASTER
6 : OPERATING
UNKNOWN ro Output
178.04 BAUDRATE PEER TO PEER ENUM 0 : INVALID
1 : 250K
2 : 500K
3 : 800K
4 : 1000K
INVALID ro Output
178.05 LAST PHY ADDR PEER TO PEER INT _ 0 ro Output
178.06 DIAGNOSTIC PEER TO PEER WORD 0000 to FFFF 0000 ro Output
179.06 VALUE ANALOG INPUT 6 REAL _.x 0.0 % ro Output
179.08 FITTED ANALOG INPUT 6 BOOL 0 : FALSE
1 : TRUE
FALSE ro Output
182.01 STATUS MODBUS RTU ENUM 0 : UNKNOWN
1 : CONFIGURING
2 : NOT ACTIVE
3 : ACTIVE
UNKNOWN ro Output
182.02 NODE ADDRESS MODBUS RTU INT _ 0 ro Output