Technical Specifications E-28
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D
Electrical Ratings: 890SD Frame B, 380-500V
Input currents are listed at 400Vac and 50Hz or 460Vac and 60Hz. Suitable for use in a circuit capable of delivering not more than
10000 rms Symmetrical Amperes. Motor power, input current and output current must not be exceeded under steady state operating
890SD-532160B
(890SD/5/0016B)
890SD-53216SB
(890SD/5/S016B)
Internal Resistor Power Rating
External Continuous Power Rating
External Minimum Resistor Rating
150% overload for 60 seconds (all vector modes) 180% for 1s (V/Hz mode)
200% overload for 4 seconds (PMAC mode)
Notes: 1) Based on a 10ms rectangular current pulse. 2) Based on 30% duty at a braking resistor appropriate for braking at 100% of drive rated power.
3) Up to the highest supply voltage that maintains shaft power less than the product power rating, for a typical induction motor. Derated for operation above this supply voltage.