EasyManua.ls Logo

Parker GVM Series - Page 15

Parker GVM Series
82 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- 15
18-06-08 PVD3668_GB_GVM_June_2018
Ip = Peak current
In = Nominal current for a define speed (For low speed In=Io)
tp = duration of the peak current in the cycle.
tc = duration of the cycle
Irms = Thermal equivalent current. ( Irms=√(Ip²*tp/tc) )
Tcp = Thermal time constanst of the copper.
 󰇟󰇭
󰇛


󰇜
󰇮 󰇭󰇭
󰇛 󰇡


󰇢 󰇜
󰇛


󰇜
󰇮󰇮󰇠



󰇭




󰇮

Example :
Motor series GVM210-400-DPW
Tcp = 39 s
Irms/In = 0.8
Ip/In = 1.4
 󰇩
󰇛

󰇜
󰇧󰇧
󰇛
󰇛

󰇜
󰇜
󰇛

󰇜
󰇨󰇨󰇪




0
5
10
15
20
25
30
35
40
45
50
0.5 0.6 0.7 0.8 0.9 1
tp (s)
Irms/In
GVM210-400-DPW
1.2
1.4
1.6
1.8
2
Ip/In

Table of Contents