4.3.2. Resolver / Encoder / Thermistor cable handling
Caution: It is forbidden to disconnect the Encoder cable under voltage (high
risk of damage and sensor destruction).
Warning: Always wear an antistatic wrist strap during encoder handling.
Warning: Do not touch encoder contacts (risk of damage due to electrostatic
discharges ESD.
Danger: before any intervention the drive must be stopped in accordance
with the procedure.