- 9
18-06-08 PVD3668_GB_GVM_June_2018
Mechanical interface
Different interfaces for Implement and Traction
Sizes (square motor dimension)
142, 210
Degree of Protection
IP67 as standard ; IP6K9K on request (IEC 60034-5)
Cooling
Water-glycol cooled, Oil cooled or Natural convection
Cooling liquid temperature
-20°C to 65°C depending on coolant characteristics
Rated voltage
24 VDC to 800 VDC
Connections
Terminal box ; Connector for feedback ;
Flying cables -only for the kit version
Insulation of the stator winding
Class H with potting
Random Vibration
0,1 g²/Hz in frequency range 5-2000 Hz
(12g rms 3 x 8h) (JDQ53.3)
Operational Shock
25g, 11ms, 3 x 6 (with 2 directions per axis)
Thermal protection
1 PTC probes and 1 KTY84-130 sensor (or equivalent)
Operating temperature
liquid cooled :
-40°C…+120°C with a Resolver sensor
-40°C…+85°C with a SinCos encoder sensor
natural convection :
-40°C…+60°C
Storage temperature
-40°C…+120°C with a Resolver sensor
-40°C…+85°C with a SinCos encoder sensor
Shaft end
Spline shaft (male or female),
other possibilities on request
Bearings
Steel ball bearings as a standard
Ceramic ball bearings and electrostatic brush as option
for high speed or in case of transient current effect risk
EHP mounting
Possibility to implement a wet-spline coupling system in
case of pump direct mounting (with front over pressure)
Sensor
Resolver or SinCos Encoder
Marking
CE