EasyManua.ls Logo

Parker HAS Series - Page 103

Parker HAS Series
125 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parker Hannifin Corporation
Cylinder Division
Des Plaines, Illinois
www.parker.com/cylinder
Hydraulic and Electrohydraulic Actuators
HAS Series Analog Drives Manual
Catalog HY08-4005-M3
104
WARNING: This product can expose you to chemicals including Lead and Lead Compounds which are known to the State of
California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
PROP 65 WARNING
Trip Table
66551111
KKeeyyppaadd
DDiissppllaayy
66990011
KKeeyyppaadd
DDiissppllaayy
DDeessccrriippttiioonn PPoossssiibbllee RReeaassoonn ffoorr TTrriipp
T 6 24V FAILURE
The 24V customer output
has fallen below 17V
Refer to Parker Hannifin technical support
T 4 VOLTS SEL SWITCH
Failure to read voltage
May be caused by excessive loading on ANOUT
PHAS PHASE LOSS
selector switch
Input phase missing
CHRG CHARGING Failed to charge DC link
Excessive capacitance on DC
link Short circuit on DC link
DCRP VDC RIPPLE Excessive DC link ripple
Driving a reciprocating load
AOUT ANOUT FAULT Overload on analog output
VOLT VOLTS SELECTION
Invalid position on
volts selector switch
ENCI ENC NEEDS INIT
PMAC motor used with
a relative encoder –
Needs to run init once
per power cycle
Relative encoder needs to be aligned with the
motor back EMF. Use MOT POLARISATION
feature to align