OOuuttppuutt SSppeecciiffiiccaattiioonn
OFF state:
Maximum applied
voltage: Reverse
voltage protection:
Leakage current:
ON state:
Maximum output current:
Overcurrent protection: Voltage
drop X11/06 to X11/05:
+30V (X11/06 relative to X11/05)
Up to -30V X11/06 relative to X11/05 Less
than 1mA when output is off.
150mA
Included, implemented by a resettable
fuse. Less than 2.5V, see below.
WWAARRNNIINNGG
WIRED CONNECTIONS TO TERMINALS
X11/01, X11/03, X11/05 AND X11/06
MUST BE LESS THAN 25 METRES IN
LENGTH AND REMAIN WITHIN THE
CUBICLE OR DRIVE ENCLOSURE.
PARKER HANNIFIN MANUFACTURING
IS NOT LIABLE FOR ANY
CONSEQUENCES IF EITHERCONDITION
IS NOT MET.
0
1
0.
5
2
1.
5
TTyyppiiccaall UUsseerr OOuuttppuutt VVoollttaaggee DDrroopp vvss CCuurrrreenntt
2.5
0 20 40 60 80 100 120
140
160
OOuuttppuutt ccuurrrreenntt ((mmAA))
OOuuttppuutt VVoollttaaggee DDrroopp
SSTTOO SSttaattuuss
IInnppuutt AA IInnppuutt BB OOuuttppuutt
XX1111//0011 XX1111//0033 XX1111//0055,, XX1111//0066
SSTTOO AAccttiivvee 0 V 0V
Drive cannot start or supply power to its motor. STO trip
reported if drive is running or drive start is attempted. This is
the intended safe state of the product with correct
dual-channel operation.
ON
24V 0V
0V 24V
SSTTOO IInnaaccttiivvee 24V 24V
Drive is enabled to run under software control. The drive can
supply power to its motor.
OFF
SSTTOO
OOvveerrvviieeww DDrriivvee FFuunnccttiioonn
AAbbnnoorrmmaall oonnee--
cchhaannnneell
ooppeerraattiioonn
ddeetteeccttiioonn
Drive cannot start or supply power to its motor. STO trip
reported if drive is running or drive start is attempted. If either
of these conditions persists for more than 3.0 seconds (the
maximum fault detection time), the STO function will lock into
a fault state. The drive cannot start until the fault is rectified,
all power is removed and reapplied (both mains and any
auxiliary 24V dc power). This is single channel operation and
thus deemed not as intended for category 3 / PLe / SIL3
structure implementation.
OFF
TTrruutthh TTaabbllee