Some safety equipment, e.g. safety PLCs, regularly pulse the two STO inputs independently in
order to detect a short circuit between them. This is commonly known as OSSD (Output Signal
Switch Device). The 890STO inputs are immune to such pulses when these are less than 2ms in
width. The product will not react to such pulses and therefore will not inadvertently invoke the STO
function.
States:
1
2
Both inputs are low. STO prevents the drive from starting. User output is ON. This is the
“safe torque off” state of the drive.
Both inputs are high, but regularly pulse low independently. External equipment can thus
detect a short circuit between the two STO user inputs. Each input must remain low for 6ms
(typical) before the 890 reacts to it.
2 1
<2ms <2ms typ 6ms
Channel A: X11/01
Channel B: X11/03
O
utput: X11/05, X11/06
STATE
24V
0V
24V
0V
ON
OFF