18.2 Guidelines for troubleshooting and rectifying errors
Problem Cause Solution
Motor will not run
No power supplied
Check the connection.
The fuse has blown
Replace the fuse,
see section A 20
.
The electric motor is
defective
Replace the motor,
see section A 40.
Motor is running but there is
no infeed
Air in the hydraulic system
Check the hydraulic system,
see section A 60.
Drive belt is defective or
slips
Check belt,
see section A 70.
No automatic shutdown of
the infeed
Air in the hydraulic system
Check the hydraulic system,
see section A 60.
The pressure switch is
defective
Check the pressure switch,
see section A 60.
Flaring pin lubrication not
working
Air in the hydraulic system
Check the lubricant supply,
see section A 50.