EasyManua.ls Logo

Parker PSD1-S - View from below (PSD1-M)

Parker PSD1-S
31 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Plug and device overview PSD1-M
16 (31) 192-011003N7 DOC-0001-01-B 11.12.23 11:39
4.2 View from below (PSD1-M)
View from above (see page 18)
X45
X43 for PSD1M_1800
Motor connections: Axis 1 ... 3 (depending on the device)
X46
X44 for PSD1M_1800
Motor brake connections: Axis 1 ... 3 (depending on the device)
X48
Connection of HIPERFACE DSL® motor feedback systems and
motor temperature sensor
Axis 1 ... 3 (depending on the device)
Front view (see page 15)
Shows pin 1 of the connector
Earthing PSD1M_1800:
Explanation
1
DSL connection
2
Connection of motor brake
3
Connect ground via ring cable lug
with a 10 mm
2
copper cable to
central ground
4
Mounting the shield clamp
1)
with
flat connection to the motor cable
shielding
5
Motor Connection
1)
The shield clamp is supplied with
the Parker motor cables.
An accessory set with several
clamps for various possible cable
diameters is optionally available for
in-house manufactured motor
cables.

Other manuals for Parker PSD1-S

Related product manuals